|
|
||||||||
From the Department of Neurology, University at Lübeck, Germany.
Address correspondence and reprint requests to Dr. M. Kaps, Ratzeburger Allee 160, D-23538 Lübeck, Germany; e-mail: Kaps-m{at}neuro.Mu-Luebeck.de
OBJECTIVE: To evaluate the diagnostic efficiency and accuracy of contrast-enhanced transcranial color-coded sonography (CE-TCCS).
BACKGROUND: TCCS is hampered by insufficient ultrasonic penetration in 20% of cerebrovascular patients.
METHODS: In 47 patients whose basal arteries could not be assessed adequately, 59 TCCS examinations were performed before and after administration of the ultrasonic contrast agent (CA) Levovist. The assessability of different basal cerebral arteries after CA administration was evaluated off-line. Angiographic records were available from 11 patients.
RESULTS: Satisfactory investigation of the middle cerebral artery, the anterior cerebral artery, the P1 and P2 segments of the posterior cerebral artery, and the supraclinoid portion of the internal carotid artery siphon was possible in 5.1%, 28.8%, 35.6%, 55.9%, and 47.5% of patients before, and in 84.7%, 91.5%, 93.2%, 94.5%, and 93.2% of patients after contrast enhancement. Stenoses or occlusions of basal cerebral arteries were registered in 28 patients (60%). CE-TCCS diagnosis was confirmed by digital subtraction angiography or magnetic resonance angiography in 10 of the 11 patients, leading to positive and negative predictive values of 0.86 and 1.00.
CONCLUSION: Contrast enhancement improves the diagnostic potential of TCCS significantly in patients with temporal bone window failure, and proved to be a reliable method for detecting middle cerebral artery and siphon occlusion.
This article has been cited by other articles:
![]() |
A. Kunz, G. Hahn, D. Mucha, A. Muller, K.M. Barrett, R. von Kummer, and G. Gahn Echo-Enhanced Transcranial Color-Coded Duplex Sonography in the Diagnosis of Cerebrovascular Events: A Validation Study AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2122 - 2127. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Gerriets, M Goertler, E Stolz, T Postert, U Sliwka, F Schlachetzki, G Seidel, S Weber, and M Kaps Feasibility and validity of transcranial duplex sonography in patients with acute stroke J. Neurol. Neurosurg. Psychiatry, July 1, 2002; 73(1): 17 - 20. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Stolz, M. Nuckel, I. Mendes, T. Gerriets, and M. Kaps Vertebrobasilar Transcranial Color-Coded Duplex Ultrasonography: Improvement with Echo Enhancement AJNR Am. J. Neuroradiol., June 1, 2002; 23(6): 1051 - 1054. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Koga, K. Kimura, K. Minematsu, and T. Yamaguchi Relationship between Findings of Conventional and Contrast-Enhanced Transcranial Color-Coded Real-Time Sonography and Angiography in Patients with Basilar Artery Occlusion AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 568 - 571. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Deklunder Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C51 - C55. [Abstract] [PDF] |
||||
![]() |
C. Klotzsch, A. Bozzato, G. Lammers, M. Mull, and J. Noth Contrast-Enhanced Three-Dimensional Transcranial Color-Coded Sonography of Intracranial Stenoses AJNR Am. J. Neuroradiol., February 1, 2002; 23(2): 208 - 212. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gerriets, E. Stolz, S. Konig, S. Babacan, I. Fiss, M. Jauss, and M. Kaps Sonographic Monitoring of Midline Shift in Space-Occupying Stroke : An Early Outcome Predictor Stroke, February 1, 2001; 32(2): 442 - 447. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gerriets, T. Postert, M. Goertler, E. Stolz, F. Schlachetzki, U. Sliwka, G. Seidel, S. Weber, and M. Kaps DIAS I: Duplex-Sonographic Assessment of the Cerebrovascular Status in Acute Stroke : A Useful Tool for Future Stroke Trials Stroke, October 1, 2000; 31(10): 2342 - 2345. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |