Neurology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Correspondence:
Submit a response
Right arrow Correspondence:
View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when Correspondence are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Whiteley, W.
Right arrow Articles by Lueck, C. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Whiteley, W.
Right arrow Articles by Lueck, C. J.
Related Collections
Right arrow Cerebrospinal Fluid
NEUROLOGY 2006;67:1690-1691
© 2006 American Academy of Neurology


Brief Communications

CSF opening pressure: Reference interval and the effect of body mass index

W. Whiteley, MRCP, R. Al-Shahi, MA, PhD, MRCP, C. P. Warlow, MD, FRCP, M. Zeidler, DM, FRCP and C. J. Lueck, PhD, FRCP

From the Division of Clinical Neurosciences, University of Edinburgh, UK (W.W., R.A.-S., C.P.W., M.Z.); and The Canberra Hospital and the Australian National University, Canberra, Australia (C.J.L.).

Address correspondence and reprint requests to Dr. William Whiteley, Bramwell Dott Building, Division of Clinical Neurosciences, University of Edinburgh, Western General Hospital, Edinburgh, EH4 2XU, UK; e-mail: wwhitele{at}staffmail.ed.ac.uk

We prospectively recorded CSF opening pressure in 242 adults who had a lumbar puncture with concomitant measurement of weight and height. The 95% reference interval for lumbar CSF opening pressure was 10 to 25 cm CSF. Body mass index had a small but clinically insignificant influence on CSF opening pressure.


Disclosure: The authors report no conflicts of interest.

Authors’ contributions: C.J.L. had the original idea for the study. W.W., R.A.S., C.P.W., and C.L. conceived and planned the study design, data collection, and analysis. W.W., R.A.S., and M.Z. conducted the study. Every author contributed to interpretation of data. W.W. and R.A.S. drafted the article, and every author revised it critically for important intellectual content. All authors gave final approval of the version to be published. C.P.W. is responsible for the overall content as guarantor.

Received May 4, 2006. Accepted in final form July 21, 2006.




This article has been cited by other articles:


Home page
NeurologyHome page
F. Bono, A. Quattrone, W. N. Whiteley, R. A.-S. Salman, C. Lueck, and C. Warlow
CSF OPENING PRESSURE: REFERENCE INTERVAL AND THE EFFECT OF BODY MASS INDEX
Neurology, April 24, 2007; 68(17): 1439 - 1440.
[Full Text] [PDF]

Correspondence:

Read all Correspondence

CSF opening pressure: Reference interval and the effect of body mass index
Francesco Bono, MD, et al.
Neurology Online, 14 Jan 2007 [Full text]
Reply from the Authors
William N. Whiteley, et al.
Neurology Online, 14 Jan 2007 [Full text]